●Small radlus of
gyration, the space before or after the entrance and exit can be utilized effectively. ●Rails are not necessary on the ground, the stretcher push car and wheelchair may enter very smoothly. ●Particularly suitable to the compartment for the operation room of hospital and aisle. |
Model | MSW-2D | MSW-4D | ||
Open and close method | Double door | Foor door | ||
Weight of door | 45kg×2 | 45kg×4 | ||
Width of door | DW=500mm∼800mm | |||
Open and close speed | 30° /Sec | |||
Power supply | AC100V∼110V 220V∼240V 50∼60HZ | |||
Power consumed | 60W | |||
Installation method | Built-in type | |||
Driving method | Timing |
●Even the narrow
space of entrance and exit can be enlarged. ●Two door plates can be moved to the same direction so as to increase double space of entrance and exit. ●To adopt two door plates with 2:1 speed to open or close door, that shall enable the operation can be more smoothly. ●The 4 door plates type can be opened or closed in left or right direction at the same time, installation of this model or separation type is more suitable to factory, warehouse, incinerator. |
Model | MSW-2D | MSW-4D | ||
Open and close method | Double door | Foor door | ||
Weight of door | 100kg×2 | 75kg×4 | ||
Width of door | DW=500mm∼1500mm | |||
Open and close speed | 180mm∼350mm/Sec | |||
Power supply | AC100V∼110V 220V∼240V 50∼60HZ | |||
Power consumed | 60W | 90W | ||
Installation method | Timing, V belt | |||
Driving method | Separation type |
●Presenting a high class and honorable entry door,to increase the integated fine appearance and practice. ●The round style inner and outer layer doors that shall constitute a closure room so as to prevent the cooling air from leakage to approach the most ideal air conditioning effect. |
Model | MC-1200R | MC-1500R | ||
Open and close method | Single door | Double door | Single door | Double door |
Weight of door | 85kg×2 | 100kg×2 | ||
Width of door | DW=700mm∼1250mm | |||
Open and close speed | 250mm∼350mm/Sec | |||
Power supply | AC100V∼110V 220V∼240V 50∼60HZ | |||
Power consumed | 60W | 90W | ||
Installation method | Built-in type, Separation type | |||
Driving method | V belt |
●Safety measures to prevent people from being clamped. ●The driving shaft can drive 2-4 door plates and is easily interchangeable. ●While in power stop or emergency, use the fasten button to fold the door plates so as to assure the access very smoothly. ●The door plates are always rotated by counterclockwise direction, while in emergency, the door plates can be pushed by clockwise direction. |
Inside diameter D | 2000 | 2400 | 2700 | 3000 |
Outside diameter B | 2143 | 2543 | 2843 | 3143 |
Clear width LW | 1320 | 1600 | 1815 | 2030 |
Escape route width F | 820 | 1020 | 1170 | 1320 |